Phaser 6500/WorkCentre 6505 Service Manual
Xerox Internal Use Only
8-63
Service Parts Disassembly
MFP Inlet Chassis
MFP PL 8.4.11 (Chassis Inlet)
1. Perform the service preparation steps on page 8-3.
2. Remove the IIT Sub-assembly. (page 8-195)
3. Remove the Top Plate Assembly (page 8-59).
4. Remove two screws (silver, tap, 8mm) that secure the Inlet Chassis to the
printer, and remove the one screw (silver, with washer, 6mm) that attaches the
grounding terminal of the Inlet Switch Assy (PL8.3.7) to the printer.
5. Release the 2 hooks that secure the Inlet Chassis to the frame, and remove the
Inlet Chassis together with the Inlet Switch Assembly.
s6500-255
Hooks