35
failure
status
4021
Charger front door opens Check whether the door is
closed, check whether the
access control spring is
working and whether the
cable is connected
EVSE
4022
Charger back door opens
Check whether the door is
closed, check whether the
access control spring is
working and whether the
cable is connected
EVSE
4023
Power module failure
Please contact XCHARGE
EVSE
4025
The vehicle demand
voltage exceeds power
module rating
Check EV
EVSE
4026
Electromagnetic lock
locking failure
Please contact XCHARGE
EVSE
4027
Electromagnetic lock
unlocking operation
failed
Please contact XCHARGE
EVSE
4028
Electromagnetic lock
reset failed
Please contact XCHARGE
EVSE
5009
The power module is not
energized
Check power module supply
EVSE
5010
Power module address
conflict
Check if the DIG switch of
the module is in right
position
EVSE
5011
PE warning
Check PE connection
EVSE
5012
AC wiring of charger lacks
phase
Check three phase
connection
EVSE
6003
Water level alarm
Check if there is water
exceeds detector
EVSE
6004
Relay check failure
Check relay
EVSE