Copyright | C6AM User Manual, Version 1.2.2
34
100F
Charger temperature
alarm
Check ventilation system,
dust filter and ventilation fan
EVSE
1012
BMS demand voltage is
above or below limits
Check EV
EV
1013
L1-phase overvoltage
Check grid input
Grid
1014
L1-phase undervoltage
Check grid input
Grid
1015
L2-phase overvoltage
Check grid input
Grid
1016
L2-phase undervoltage
Check grid input
Grid
1017
L3-phase overvoltage
Check grid input
Grid
1018
L3-phase undervoltage
Check grid input
Grid
1023
Discharge check failure
Check power module
EVSE
1025
Insulation check failure
Please contact XCHARGE
EVSE
1080
Power module check
failure
Please contact XCHARGE
EVSE
10A0
SPD warning
Check SPD status
EVSE
10B0
PE warning
Check PE connection
EVSE
2005
Plug 1 temperature alarm Check status of plug 1
EVSE
2006
Plug 2 temperature alarm Check status of plug 2
EVSE
2016
Plug DC contactor failure
Check plug DC contactor
status
EVSE
2017
EV battery reverse wiring
Check EV
EV
2018
EV battery voltage
abnormal
Check EV
EV
2019
EV battery overvoltage
Check EV
EV
2021
EV battery undervoltage
Check EV
EV
4002
The emergency stop
button is pressed
Check the cause of
emergency stop, restore
emergency button
Unknown
4009
Switch DC contactor
Check switch DC contactor
EVSE