4.2 Installation Environment
The installation shall not be made in a commercial garage (repair facility) or closer than 20
feet (508 mm) of an outdoor motor fuel dispensing device.
WARNING
Danger of life through improper installation!
Ignoring the environmental conditions can lead to dangerous situations when dealing
with electricity.
When installing the charging device outside, avoid direct sunlight of the display, which
will impact the ability to scan code for installation.
Do not install and use the charging device near flammable, explosive, rough or
combustible materials or chemicals or steam.
The concrete space needs to be able to withstand four times the load.
4.3 Construct Foundation
4.3.1 Concrete Foundation
The C6AM charging station can be built on a concrete foundation. The flat surface of
foundation should not be larger than the dimension of 800 mm * 800 mm. For the entrance
of the cable, a hole should be provided in the foundation corresponding to the type of power
cable, which was dimensioned in Figure 4.3.1 as an example for the C6AM 150kW. If you do
not use a Prefabricated foundation, please notice the hardening times of the applied concrete
before installation.
Figure 4.3.1 Concrete foundation for 150kW C6AM
The height of the foundation is determined by the terrain of the site. Depending on rainfall and
drainage a height between 15 cm and 30 cm above the ground is recommended by XCHARGE.
Because of frost-proof the foundation must be about 80 cm deep under the ground.