Installing the XPower Plus
445-0145-01-01
3–17
10. Before proceeding, double check that the cable you have just installed
connects the positive DC terminal of the inverter to the fuse holder,
and that the other end of the fuse holder is connected to the positive
terminal on the battery.
.
11. Connect the cable from the negative post of the battery to the negative
DC terminal of the inverter.
12. Install the lock washer and nut that are supplied. Tighten the nut to a
torque of 11–13 foot pounds (16–18 Nm). Make the connection snug
enough so the ring terminal does not move around on the DC
terminal, but do not overtighten.
CAUTION
Loose connections cause excessive voltage drop and may cause
overheated wires and melted insulation.
CAUTION
Do not over tighten the nut on the DC input terminals. Damage to the DC
input terminals may result.
The maximum torque setting is 11–13 foot pounds (16–18 Nm).
CAUTION: Reverse Polarity
DC power connections to the
XPower Plus
must be positive to positive
and negative to negative.
A reverse polarity connection (positive to negative) will blow a fuse in the
inverter and may permanently damage the inverter. The fuse is not user
replaceable and the inverter may need to be returned for servicing.
Damage caused by a reverse polarity connection is not covered by your
warranty.
WARNING: Explosion or Fire
Do not complete the next step if flammable fumes are present. Explosion
or fire may result. Thoroughly ventilate the battery compartment before
making this connection.
XPower 1200 Plus 1750 Plus.book Page 17 Friday, October 21, 2005 4:19 PM