Installation
3–14
445-0145-01-01
Connecting the Chassis Ground
The
XPower Plus
has a screw terminal labelled
CHASSIS GND
on the
rear panel as shown in
Figure 3-3
. Follow the guidelines in
“Grounding
Locations”
to connect the inverter’s chassis to the ground.
Grounding Locations
You must connect the chassis ground terminal to a grounding point. The
grounding point varies depending on where you install the
XPower Plus
.
•
For recommended chassis ground cable size for the
XPower 1200
Plus
, see
“Calculating Size of Chassis Ground Cable for XPower
1200 Plus” on page 3–7
.
•
For recommended chassis ground cable size for the
XPower 1750
Plus
, see
“Calculating Size of Chassis Ground Cable for XPower
1750 Plus” on page 3–9
.
Follow the instructions that correspond to your type of installation:
To connect the chassis ground terminal to a grounding point:
u
Recreational Vehicle: Connect the
CHASSIS GND
screw to the
vehicle’s chassis using recommended copper wire (if insulated then
green insulation with or without one or more yellow stripes) or larger.
WARNING: Electrical Shock Hazard
Never operate the
XPower Plus
without properly connecting the chassis
ground. Electrical shock hazard could result from improper grounding.
Figure 3-3
DC Panel Connections (XPower 1750 Plus shown)
XPower 1200 Plus 1750 Plus.book Page 14 Friday, October 21, 2005 4:19 PM