Installation
3–18
445-0145-01-01
This the last cable connection. If you do not have a battery selector
switch that is between the inverter and batteries, and that is in the Off
position, a spark is normal when you make the connection. The
connection sequence in Step 12 ensures that the spark happens away
from the batteries, reducing the risk of fire or explosion.
13. If you have installed a battery selector switch, use it to select one of
the batteries or battery banks (house bank preferred over start bank).
14. Move the inverter’s On/Off switch to the On position.
The Power light should come on, indicating that the XPower Plus is
ready for operation.
15. Check the
INPUT VOLTAGE DISPLAY.
It should read between 12
and 13 volts, depending on the condition of the battery. If it does not,
check your battery and the connection to the inverter, and the state of
charge of the battery.