Introduction
1–10
975-0402-01-01
This guide for use by qualified installers only
The Fault LED works in conjunction with the Charging
Current (%) LEDs. The icons at the top row above the
Charging Current (%) LEDs represent the various types of
fault and warning conditions. For example, a temperature
warning is represented by a thermometer icon.
The Charging Current (%) LEDs will normally illuminate as
a solid progress bar when they are indicating the amount of
output charging current. If any of the LEDs start to flash
intermittently at the same time that the Fault LED is either
solid or flashing, a fault or warning condition is indicated.
5
Battery Type Select button
Press and hold the button for three seconds to select either of five
settings. An indicator LED corresponds to each setting. Each setting
maximizes charger performance for its corresponding battery type.
•
AGM
- Absorbent Glass Mat lead-acid battery
•
Flooded
- Lead-acid battery; default setting
•
GEL
- Gel-type lead-acid battery
•
Lead Calc.
- Lead-calcium battery
•
Custom
- If a custom battery type has been programmed then all
LEDs will illuminate
6
Battery Temp. Select button
•
Press and hold the button for three seconds to select one of three
settings. An indicator LED corresponds to each setting. Each
setting will change the charger’s internal threshold to compensate
for variance in battery voltage due to a change in temperature.
•
Cold
- for battery temperature below 5 °C (41 °F)
•
Warm
- for battery temperature between 5 and 30 °C
(41 and 86 °F); default setting
•Hot
- for battery temperature above 30 °C (86 °F)
•
When setting or cancelling an Equalization program: Press and
hold both the Battery Temp. Select and Charger Mode Select
buttons.
Item Description
TC2 Series BattChg Install Guide.book Page 10 Monday, June 30, 2008 3:18 PM
Содержание Truecharge TC1012
Страница 2: ......
Страница 32: ...1 18 This guide for use by qualified installers only...
Страница 73: ......