Basic Installation Procedures
26
Freedom XC 1800 (12VDC) Owner's Guide
NOTICE
EQUIPMENT DAMAGE
n
Do not connect any AC source (such as a generator or
utility power) to the
AC output wiring
of the Freedom
XC.
n
The Freedom XC will not operate if its output is connected
to AC voltage from another source, and potentially
hazardous or damaging conditions may occur. These
conditions can occur even if the inverter/charger is off.
Failure to follow these instructions can result in equipment
damage.
Do not connect the Freedom XC to an AC branch circuit that has
high-power consumption loads.
The Freedom XC will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than
its rated output wattage.
AC Output Connections
To make a connection:
1. Ensure AC and DC power sources are turned off, if not
already done from
AC Input Connections on page 24
.
2. Install the required circuit breaker in the inverter/charger
distribution panel receiving AC power from the
inverter/charger.
3. Attach the compatible connector from the AC output cable to
the receptacle on the unit as shown.
Figure 9 Routing and connecting the wires
c
Attach the correct mating connector to avoid exposure to live
wires.
4. Connect the other end of the AC output cable to a circuit
breaker in AC distribution panel providing AC power to the
loads.