Adjusting Feature Settings in Configuration Mode
46
Freedom XC 1800 (12VDC) Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of Values
Description
Utility AC Under
Voltage Level
12
90
85
to
110
In V
V
Inverter Shutdown
Recovery
13
MAT
At0
(auto-restart)
MAT
(manual restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting
ATO
(auto-
restart) will allow the inverter/charger to recover automatically
from a shutdown up to three times maximum. Selecting
MAT
(manual restart) allows the user to restart the inverter/charger
by performing a manual reset, that is, by acknowledging the
restart via the display panel.
Audible Alarm
14
bON
bON
(Audible)
BOF
(Mute)
The alarm beeps once every 5 s.
Battery Type
20
AGM
FLD
(Flooded),
AGM
(AGM),
GEL
(Gel)
USE
(Custom)
LFP
(LiFePO
4
)
The use of
LFP
(LiFePO
4
) as a battery type requires a
compatible BMS. See
.
Battery
Temperature
21
VRM
CLD
(Cold)
VRM
(Warm)
HOT
(Hot)
Selecting Cold from Warm will increase charger voltage by
0.4V.
Selecting Cold from Hot will increase charger voltage by 0.8V.