AC/DC and GFCI Panel
8
Freedom XC 1800 (12VDC) Owner's Guide
Feature
Description
6
DC terminal
opening for routing (–) negative DC
cable.
7
DC terminal
opening for routing (+) positive DC
cable.
8
LED indicator
for reverse DC polarity.
9
AC output terminal
for connecting AC output cable
with matching connector.
10
AC input terminal
for connecting AC input cable
with matching connector.
11
GFCI
duplex receptacle.
12
Mounting flanges
on both sides allow you to mount
the inverter/charger permanently on deck or on a
wall.
13
Ventilation grille
(openings) must not be obstructed
for the proper operation of the cooling fan and
inverter/charger. When the inverter/charger is
mounted, the ventilation grille must not point up or
down.
Cooling fans
turn on when the internal temperature
reaches a set point temperature.
Feature
Description
14
Press to recover from an overload condition.
Provides protection for the wiring of the GFCI duplex
receptacle AC output.
WARNING
ELECTRICAL SHOCK HAZARD
n
Use a torque screwdriver to tighten the bolt on the DC
ground lug to a torque of 23 in-lb (2.6 N-m) of force.
n
Apply an anti-corrosion compound to the copper wire prior
to connecting to the DC ground lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.