Adjusting Feature Settings in Configuration Mode
975-1175-01-01
47
Setting Name
Setting
Number
Default
Value
Range of Values
Description
Custom Absorption
Voltage
22
14
.
6
12
.
0
to
18
.
0
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
Custom Float
Voltage
23
12
.
0
to
18
.
0
Charger Current
24
5
to
80
The current setting value can be adjusted by 5A increments.
Charger Ignition
Control
26
OFF
OFF
(OFF)
AT0
(Auto-ON)
See
Description of Ignition Control Features on page 32
.
Equalize Charging
for Flooded Battery
27
DIS
ENA
(enable)
DIS
(disable)
This setting is only available when Flooded battery type is
selected. It allows only one hour of equalize charging once.
AC Input Breaker
for Load Share
28
15
5
to
15
The load share feature prioritizes the AC load by reducing the
charge current in order to maintain the total input current to
less than the load share setting.
Reset all settings to
their default values
99
ndf
NDF
(as is)
DEF
(default)
ndF
refers to current settings.
Choose
def
to restore all settings to their default values.