![Xantrex Freedom XC 1800 Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/xantrex/freedom-xc-1800/freedom-xc-1800_owners-manual_3218840088.webp)
System Specifications
74
Freedom XC 1800 (12VDC) Owner's Guide
System Specifications
Freedom XC 1800 (12VDC)
Transfer relay rating (A
a
)
20A
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20 milliseconds
<20 milliseconds with a 20-
second delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<85 V and >140 V
<135 V and >90 V
Cooling
Fan, activated by any of the
following:
High internal temperature
High AC output power
Table 18 System specifications
a
Circuit breakers shall not carry more than 80% of their UL rating continuously.
b
To change the AC Transfer time (mode), see
Adjusting Feature Settings in Configuration Mode on page
.
Freedom XC 1800 (12VDC)
Operating voltage range
LBCO voltage
a
–18.0 VDC
Maximum non-operating voltage
24 VDC
Nominal voltage
12 VDC
Nominal current at full load
173 ADC
Table 19 DC input for inverting
Freedom XC 1800 (12VDC)
Output voltage options
120, 110, 108 VAC
Continuous power
b
1800 W @ 40 °C
Continuous current
15 A
rms
Surge power (2 sec)
3600 W
Frequency
c
60 (or 50) Hz
GFCI protection downstream
Required (customer-provided)
Wave shape
True sine wave
Peak efficiency
91%
Full load efficiency
≥
87.5%
Table 20 AC output for inverting
a
To set LBCO, see
Adjusting Feature Settings in Configuration Mode on page 43
b
Power derates to 85% when output voltage is set to 110/108 VAC (120VAC default).
c
To set the AC Frequency, see
Adjusting Feature Settings in Configuration Mode on page 43
.