Operating in Battery Mode
48
Freedom XC 1800 (12VDC) Owner's Guide
Operating in Battery Mode
The Freedom XC is in Battery Mode (also called Inverter Mode)
when all the following conditions exist:
n
inverter power button is ON
(down position)
n
shore power is not presently available
n
battery has sufficient power
Inverter operation means that DC battery power is presently being
converted to utility grade AC power, powering equipment and
appliances connected to the AC output terminal of the unit. The
green status LED lights up to indicate the Freedom XC is using
the battery to power the equipment and appliances.
BATT.MODE
Turning Inverter Operation ON and OFF
n
Press the Power button to a down position (it is in Standby
in the up position).
WARNING
ELECTRICAL SHOCK HAZARD
Turning the Power
k
button to Standby mode does not disconnect
DC battery power from the Freedom XC. You must disconnect from
all power sources before working on any circuits connected to the
unit.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
To prevent unnecessary battery discharge, press the Power
button to Standby when you are not using the Freedom XC.
Power Save Timer
The Power Save Timer is an adjustable countdown timer from 1 to
25 h ( is the default) that automatically shuts down inverter
operation to reduce battery discharge and preserve battery life.
During continuous inverter operation, the countdown is initiated
when power from the AC load drops to less than approximately 50
W and remains below this level. After reaching the end of the
countdown timer the inverter/charger automatically shuts down.