44
Freedom SW Owner’s Guide
Configuring the Freedom SW using the SCP
Table 5
Configurable Settings
Item
Description
Inverter
Enables or disables the inverter function of the
Freedom SW. When enabled, the unit will
invert power from the batteries assuming there
is enough charge in the batteries.
Default value is Enabled.
Search Mode
Enables or disables the Search Mode function
of the Freedom SW. See “Using Search Mode”
on page 45 for more information.
Default value is Disabled.
Charger
Enables or disables the charger function of the
Freedom SW. When enabled, the unit will
charge the batteries when AC is available. For
more information on configuring the charger
settings go to “Charger Settings Menu” on page
59.
Default value is Enabled.
Auto Chg
Enable
Forces the Freedom SW to charge the batteries
when qualified input AC is detected even when
the charger function is disabled.
Equalize
Initiates the battery equalization process. See
“Equalization Procedure” on page 47 to enable
the procedure.
Default value is Disabled.
Desired Mode
Switches between Operating and Standby
(Power Save) modes.
Default value is Operating.
Clear Faults
Warning
Clears any active faults and warnings.
Basic
Settings
See “Changing Freedom SW Basic Settings” on
page 48 for more information.
Advanced
Settings
See “Changing Freedom SW Advanced
Settings” on page 52 for more information.
Table 5
Configurable Settings
FSW Owners Guide.book Page 44 Tuesday, August 7, 2018 9:03 AM
Содержание Freedom SW 815-2012
Страница 2: ...FSW Owners Guide book Page ii Tuesday August 7 2018 9 03 AM ...
Страница 14: ...FSW Owners Guide book Page iv Tuesday August 7 2018 9 03 AM ...
Страница 30: ...FSW Owners Guide book Page 16 Tuesday August 7 2018 9 03 AM ...
Страница 116: ...FSW Owners Guide book Page 102 Tuesday August 7 2018 9 03 AM ...