94
Freedom SW Owner’s Guide
Troubleshooting
F49
DC Over
Voltage
Automatic
Voltage at the DC
input terminals is
above the High
Battery Cut Out
Setting
Clear the fault and attempt restart.
Ensure battery voltage is 10–16 VDC
at Freedom SW terminals. Check all
other charging source outputs, battery
cables.
F52
-
F56
EEPROM ERROR
Manual
A problem has been
detected with the
internal memory.
Clear the fault and check the latest
configuration made or any recent
configurations. If fault detection
reoccurs or occurs frequently, service
is required.
Table 3
Detected Fault Messages
Fault
Number
Message
Fault Type
Cause
Solution