Configuring the Freedom SW using the SCP
The Freedom SW supports the generator or shore power when
the AC load current drawn from the generator or shore power
exceeds the
GenSup Amps
setting for one to two seconds.
The system can enter this state if the battery voltage is above
Low Battery CutOut (LBCO)
plus 1 volt and
GEN
Support
is enabled.
GEN Support
with a generator can only
work when the Xanbus AGS is installed and detected in the
system to control when to turn on the generator.
GEN
Support
with shore power, however, does not need the
Xanbus AGS.
GenSup
Amps
Sets the generator or
shore power load
level at which the
Freedom SW
supplies power from
the batteries to
support the
generator or shore
power.
24A
4A
to
24A
a. Applies to all Freedom SW models.
Table 16
GEN Support Menu Description and Values
a
Setting
Description
Default
Range
FSW Owners Guide.book Page 67 Tuesday, August 7, 2018 9:03 AM