Installing the Gateway
975-0330-01-01
2–5
Other Materials and Tools
p
Additional Ethernet cable (for connecting the Gateway to a router) or
crossover cable (when connecting the Gateway directly to a
computer)
p
Xanbus power supply (required when connecting the Gateway to a
single GT Inverter manufactured before spring 2008)
For a network power supply, contact Xantrex at 1 800 670-0707 or
[email protected].
p
Weatherproof enclosure (required for outdoor installations, part
number 864-0500)
p
Phillips screwdriver
p
Power drill
p
Cable clamps or hardware fasteners.
Mounting the Gateway
Indoors
Mount the Gateway on a wall with the connectors facing downwards. For
Gateway dimensions, see Figure A-1 on page A–3.
To mount the Gateway:
1. Hold the unit flush and square against the wall, panel, or horizontal
surface.
•
If the mounting surface requires pre-drilled holes for the screws,
use the supplied mounting template to mark, then drill, four
holes.
2. With a Phillips screwdriver and the supplied #6 screws, secure each
corner of the Gateway to the mounting surface.
Outdoors
Outdoor Gateway installations require the Gateway to be mounted inside
a weatherproof enclosure. A Gateway weatherproof enclosure (part
number 864-0500) is available from Xantrex.