Installation
2–4
975-0330-01-01
Materials and Tools Required
The following materials and tools are required to install the Gateway.
Supplied Materials
p
Gateway
p
10 ft (3 m) Xanbus network cable (standard straight-through Ethernet
cable—CAT 5e)
p
Four #6 screws
p
Network terminators (supplied with the Gateway and the inverter).
Figure 2-1
Maximum Distances Between Devices
130 ft
(40 m)
300 ft
(90 m)
(Wireless)
Varies
with
router
Router
Personal Computer
Gateway
Inverter
CAUTION: Equipment damage
Do not use crossover cable for the Xanbus network cable. On crossover cable, the
order of color-coded wires at each end of the cable is different.