SmartPad LCD
Page:
51
© 2003 Xantech Corporation
1. The STATUS LED on the front of the SPLCD Panel will be turned ON (Requires
TRACK LED
SETTING
to be set to
YES
).
2. Initiate a SENSE TRIGGER MACRO (if one is programmed under the
ON
button)
3. Utilize INTELLIGENT POWER MANAGEMENT (needs to be selected under the
SENSE
TAB)
Note:
Items 1&2 or 1&3 may be programmed to occur simultaneously.
OUTPUT
When
OUTPUT
is selected, the STATUS Line can be programmed to transition to a 12VDC signal via an
Internal Command (STATUS LINE SET) placed under a GTL. This can be utilized to control and external
component via a 12V trigger whenever a GTL is pressed (i.e. Control a Screen Drop or Lift via a 12VDC Trigger
or turn on a remote amplifier).
Note:
The STATUS output is rated at 15mA maximum.
BACKLIGHT CONTROL
Set the Backlight to stay ON for a specified amount of time after the last touch. The Backlight can be set to stay
ON from 1 to 30 seconds or to stay ON always.
Note:
The IR receiver is disabled whenever the Backlight is ON. Therefore if
ALWAYS ON
is selected, the IR
Receiver will not be active.
DISPLAY ORIENTATION
The LCD Display needs to be configured for the proper viewing angle according to the position it will be
installed with regard to the user.
UP
Select this setting if the SPLCD will be installed at a height equal to or above the users eye level.
DOWN
Select this setting if the SPLCD will be installed at a height equal to or below the users eye level.
UP VIEW
DOWN VIEW
Figure 33