System Settings > Snapshot:
Snapshots can be created during the measurement to track particularly
interesting time periods. The moment you raise the corresponding trigger,
all data received for a user-definable time before and after this moment, are
stored in an additional snapshot measurement.
Measurement data are processed as queues on the log interfaces. In
addition to the default-queue for packet data, the X
ORAYA
Z7 is able to use
the faster stream-queue where Ethernet data are saved directly without
creating statistics. You can set snapshots for both queues separately.
Setting the snapshot:
Configure the snapshot of the desired queue.
Create one or multiple triggers for the action
logger.snapshot
.
(
Trigger)
or
Activate the property
snapshot_on_log_press
of the button interface.
(