The X
ORAYA
Z7 is equipped with an intelligent energy management system
that lowers power consumption to about 1 mA (at 12 V supply voltage) in
sleep mode.
The device goes into sleep mode via the following actions or under the
following conditions:
Pressing and holding the power button
(K)
for at least 2 seconds.
Current recording stops automatically.
If no data reach the log interfaces and no connection to the
X
ORAYA
Suite is established for 10 minutes, the X
ORAYA
Z7 shuts down
automatically. This behaviour is configured using the main setting
Automatically Switch Off
. (
Main Settings)
Users can wake up the X
ORAYA
Z7 from sleep mode as follows:
Pressing the power button
(K)
Switching the power supply off and on
Signal change from 0 V to +12 V at the trigger or wake input
(L)
Pressing the trigger/wake button
(J)
Activity on a wakeable log interface
4.6
Connecting the X
ORAYA
Z7 to the PC
This section describes how to connect the X
ORAYA
Z7 to the PC. To do so,
you will need a standard network cable.
Proceed as follows to connect:
Connect the network cable to a switch.
or
Connect the network cable directly to your PC.
Connect the network cable to one of the LAN host ports
(E)
on the
X
ORAYA
Z7. (
Connections and controls)
The X
ORAYA
Z7 is fully connected.