34
DEU
ENG
NDL
FRA
ITA
ESP
The Service level of the base station Wireless Display is protected with a PIN code and may only
be used by authorized specialists.
Attention! Faulty configuration leads to errors and damage to installations.
¾
Press the rotary control.
¾
Select the menu “Service Level” and activate by pressing.
¾
Enter the 4-digit PIN (standard: 1234) by rotating and pressing.
¾
Select parameters (PAr) by pressing again and enter the number code of the desired param-
eter (see following table).
¾
Change parameters as required and confirm by pressing.
4.5.2 Configuration with room control unit Wireless Display
No.
Parameters
Description
Unit
010 Used heating system
Adjustable per heating zone: Floor heating (FBH) standard /
FBH low energy / radiator / convector passive / convector
active
FBH St.=0
FBH NE=1
RAD=2
KON pas.=3
KON act.=4
020 Heating/cooling block
Blocking the switching outputs depending on the activated
operating mode (heating/cooling)
normal=0
Heating block=1
Cooling block=2
030 Operation lock
(child safety lock)
Unlocking the operating lock with password protection
Deactivated=0
Activated=1
031 Operating lock password
Determine PIN if parameter 30 is set to active
0000..9999
4.5.1 System configuration with microSD card
Individual settings can be made via the EZR Manager SD Card under www.ezr-home.de and
transferred to the base station via the microSD card. As of software version 01.70, the base station
accepts microSD cards >2 GB in the formats FAT16 or FAT32.
¾
Open www.ezr-home.de in the web browser of your PC, select EZR Manager SD Card and
follow the instructions on-line.
¾
Insert the microSD card with the updated data into the base station.
9
The transfer process will start automatically and copy the updated data into the base sta-
tion.
9
The LED “syBUS” flashes during the transfer process.
9
After a successful data transmission, the LED “syBUS” goes out.
4.5 System configuration
The configuration of the base station is done optionally via the microSD, the software interface of
the Ethernet variant or the Service level of the room control unit Bus Display.