3-3
Quick Start Guide
3.2.2. Access via Network
Before you can communicate with the VIP via network, you must first
access command mode via the Console Port or Modem, and set up network
parameters as described below.
1.
Access Command Mode:
Access the VIP command mode via
Console Port or Modem as described in the previous section. When
the READY message appears, press
[Enter]
to display the main menu.
2.
Configure the Network Port:
At the Main Menu, type
22
and
press
[Enter]
to display the Port Configuration Menu. At the Port
Configuration Menu, type
6
and press
[Enter]
to display the Network
Port Configuration menu (Figure 3.2):
Note:
Consult your network administrator to determine
appropriate IP settings.
a)
IP Address:
Type
1
and press
[Enter]. (Default = undefined.)
b)
Subnet Mask:
Type
2
and press
[Enter]
.
(Default = 255.255.255.0)
c)
Gateway Address:
Type
3
and press
[Enter]
(If needed.)
(Default = undefined.)
3.
Save Configuration Parameters and Exit Command Mode:
Press
the
[Esc]
key several times to return to the main menu. From the
main menu, type
7
and press
[Enter]
to save the network parameters
entered in Step 2 above. After parameters have been saved, type
8
and
press
[Enter]
to exit from command mode.
NETWORK PORT: NIC Installed
COMMUNICATION SETTINGS OUTPUT PARAMETERS
1. IP Address: 192.168.168.168 21. Output Mode: ASCII Record
2. Subnet Mask: 255.255.255.0 22. Data on ^B01: On
3. Gateway Addr: (undefined) 23. Hold End Data: On
4. SNMP Manager 1: (undefined) 24. Line # Tag: Off
5. SNMP Manager 2: (undefined) 25. Send Compress: Off
6. SNMP Community: public 26. Auto Delete: On
7. Reset Network
8. Send MSS: 1460 OUTPUT PARAMETERS (BINARY BLOCK)
9. Send Email 27. Transmit Att: 3
10. Ping 28. Transmit Delay: 5 Secs
29. DLE Stuffing: Off
GENERAL PARAMETERS
11. Command Echo: On
12. Response Type: Inhibit Menu
13. “Sure” Prompt: On
14. CMD Timeout: 15 Mins
15. Audit Trail: Off
ACTION PARAMETERS
16. Action Delay: 10 Secs
Enter selection, Press <ESC> to return to previous menu ...
Figure 3.2: The Network Parameters Menu
Содержание PollCat NetLink NLJ-VIP
Страница 1: ...WTI Part No 13602 Rev A PollCat NetLink VIP NLJ VIP PollableCallAccountingTerminals User s Guide...
Страница 2: ......
Страница 16: ...2 4 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 28: ...4 8 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 90: ...7 26 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 126: ...10 6 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 140: ...13 8 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 150: ...15 6 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 252: ...Apx 22 PollCat NetLink VIP PollCat NLJ VIP User s Guide...
Страница 263: ...Index 11 Index...
Страница 265: ......
Страница 266: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...