TReX User Manual v15.30 Firmware
Protocol Commands
*SENT_RESP
Configures the response sent out the serial port at the completion of each transmitted message.
Considering the transmitted message: WT1234560A10 Test\r
Set the serial output to the default WT[xxx] as defined by WT Protocol.
*SENT_RESP=<CR>
typical response:
WT[090,017]
Set the serial output to “Page Sent”
*SENT_RESP=PAGE SENT<CR>
typical response:
Page Sent
Set the serial output to payload of transmitted message
*SENT_RESP=*<CR>
typical response:
Test
Set the serial output to the full sent message
*SENT_RESP=**<CR>
typical response:
WT1234560A10 Test
If the command WT1234560A11 TEST is sent to the TReX, the serial output will echo the full
WT protocol command including the message payload.