TReX User Manual v15.30 Firmware
*TEMP
Returns temperature of first the digital board, then the RF temperature sensor. This is NOT the
ambient temperature. Temperatures in excess of 100 degrees C are completely normal under
typical transmitting operation.
Usage:
*TEMP<CR>
Typical output:
TEMP=DIG:55.0C RF:60.1C
*PWR
Returns current forward power ADC count and system current both at the time of reading and
recorded during the last transmission.
Usage:
*PWR<CR>
Typical output:
*PWR=500,34,160,0.28,1.23
The first parameter is the forward power ADC count at the time of reading. The second value
is the forward power recorded during the last message transmission. Parameter 3 is the RF
output drive value used to achieve the ADC count. Parameter 4 is the system current.
Parameter 5 is the system current recorded during the last message transmission.
*VER
Sends the TReX sign on message back to the user. This is useful to determine the model and
serial number of the unit.
Usage:
*VER<CR>
*RTC_DATE
Sets the TReX clock date. Format is DD/MM/YY,W
Where:
DD is day of the month (1-31)
MM is the month (1-12)
YY is the year (0-99)
W is optional day of the week, MON-SUN (1-7)
Typical Usage:
© WTE Limited, 2022 – Christchurch New Zealand
Page 104 of 302
Содержание TReX-460
Страница 87: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 87 of 302...
Страница 193: ...TReX User Manual v15 30 Firmware output of FAILED CR WTE Limited 2022 Christchurch New Zealand Page 193 of 302...
Страница 280: ...TReX User Manual v15 30 Firmware SIDE Mount WTE Limited 2022 Christchurch New Zealand Page 280 of 302...
Страница 281: ...TReX User Manual v15 30 Firmware Bottom Mount WTE Limited 2022 Christchurch New Zealand Page 281 of 302...
Страница 286: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 286 of 302...
Страница 302: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 302 of 302...