7.2.
Ecreso FM and Ecreso FM Amplifier serial commands
7.2.1.
System commands
Greyed out commands are Ecreso FM only commands.
NAME
Access
(R/W)
Possible value on the serial port of
the unit
Comments
LOGIN
R/W
XXXX,X=[0…z] "LOGGED" or "NOT
LOGGED"
Logs the user and allows them to update
variables if the password is correct. Returns
Logged or not logged
LOGOUT
W
Logs out the user and locks all variables.
SYS.CID
R/W
[0..31]
Unit identifier used by the CAN bus.
SYS.CIDIP
R/W
[0..31]
Unit identifier used by the IP CAN bus
SYS.CIDUC
R/W
[0..31]
Unit identifier used by the CAN2 bus.
SYS.COM1.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial port
SYS.COM1.SPEED
R/W
9600,19200,38400,57600,115200
Speed of the rear panel serial port 1
SYS.COM2.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial port
SYS.COM2.SPEED
R/W
9600,19200,38400,57600,115200
Speed of the rear panel serial port 2
SYS.DATE
R/W
DD/MM/YY
Reads and sets the amplifier date
SYS.DATECALIB
R
DDMMYYYY
Date of the last calibration
SYS.GPIO.CONF1
R/W
"AMB" or "FAN1" or "VOLT" or
"HEAT" or "FAN2" or "CURRENT" or
"PWR"
Sets the RC ANA3 on an analog GPIO board
SYS.GPIO.CONF2
R/W
"AMB" or "FAN1" or "VOLT" or
"HEAT" or "FAN2" or "CURRENT" or
"PWR"
Sets the RC ANA4 on an analog GPIO board
SYS.GPIO.IN.ACT
R
XX X=[A..F;0..9]
Indicates the corresponding RC when managed
manually (see SYS.GPIO.IN.MASK)
SYS.GPIO.IN.MASK
R/W
XX X=[A..F;0..9]
Sets the RC control either by the control board
or manually. Hexadecimal code: each bit
corresponds to an input. Ex: A1 (10100001)
indicates the RC 1, 6 and 8 are managed
manually
SYS.GPIO.OUT.ACT
R/W
XX X=[A..F;0..9]
Enables the corresponding RM when managed
manually (see SYS.GPIO.OUT.MASK)
SYS.GPIO.OUT.MASK
R/W
XX X=[A..F;0..9]
Sets the RM control either by the control board
or manually. Hexadecimal code: each bit
corresponds to an input: Ex: 21 (00100001)
indicates RM 1 and 6 are managed manually.
SYS.HARDREL
R
xx.xx.xx x=[0..9]
Hardware version: example "3.0.1"
SYS.INIT
R/W
XXXX ; X=[0…F]
Reinitialization
flag.
b0=complete
reset
b1=SYS.PASSWORD_RST
SYS.IP.ADR
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP address of the IP board
SYS.IP.GW
R/W
XXX.XXX.XXX.XXX X=[0…9]
Network gateway of the IP board
SYS.IP.MAC
R/W
XX:XX:XX:XX:XX:XX:XX:XX X=[A..F;0..9] Mac address of the IP board
SYS.IP.MASK
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP mask of the IP board
SYS.KEY.ADD
R/W
ADD
Generates a key to enable the specified option
SYS.KEY.REM
R/W
REM
Generates a key to disable the specified option
SYS.LCDMENUS
R/W
"NORMAL" or "ADVANCED"
Sets the display type on the front panel screen
SYS.LOCALCOM.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the front panel serial
port
SYS.LOCALCOM.SPEED
R/W
9600,19200,38400,57600,115200
Speed of the front panel serial port