ECRESO FM 100/300 W, user manual– 06/2015
Page 13
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.worldcastsystems.com – [email protected]
2.3.2.
Rear panel
TCP/IP communication board
2 RS232 ports (COM1 and COM2)
1 µSD card
1 USB port
1 Ethernet port
1 CAN port
1 DIN port
On the TCP/IP board, the COM1 port is used to send serial commands, the COM2 port is used for dynamic PS tags.
The DIN port is used to reprogram the module (only to be used for maintenance).
The µSD card is an external storing device meant to mostly stay in place. Removing and setting it back triggers
error messages visible on the embedded web site; it should therefore only be done during maintenance operation
procedures. See section 5.15 for the µSD card removal procedure.
* The
optional
RF metering board
measures the power on modular systems (1 ECRESO FM + several amplifiers FM).
The values for the direct power and the forward power can be retrieved in the TX menu on the front panel or with the
serial commands TX.PFWD and TX.PREF.
** The safety loops must be closed to ensure the transmitter will work. If nothing is connected to these connectors,
interlock plugs must be present to close the loop.
Forward power
Reflected power
3 dB fault
VSWR fault
The board is detected and in
normal use
Mains
Communication board
Interlock **
GPIO slot
(option)
Ground
MPX/SCA1
MPX/SCA2
19 kHz
Audio input Line1
(Ana or AES)
Audio input Line2
(Ana or AES)
N RF output
RF metering board
(option) *