10.2.2.
Remote control function pinout
Function
Remote Control
Input name
Common
POWER ON / PRESET 1*
RC1
OPT1A(20)
RC_COMMUN(24)
POWER OFF / PRESET 2*
RC2
OPT2A(8)
RC_COMMUN(24)
RF ON / PRESET 3*
RC3
CONF1(21)
RC_COMMUN(24)
RF OFF / PRESET 4*
RC4
CONF2(9)
RC_COMMUN(24)
TA ON / PRESET 5 or 1*
RC5
CONF3(22)
RC_COMMUN(24)
TA OFF / PRESET 6 or 2*
RC6
CONF4(10)
RC_COMMUN(24)
DSN MAIN / PRESET 7 or 3*
RC7
CONF5(23)
RC_COMMUN(24)
DSN ALT / PRESET 8 or 4*
RC8
CONF6(11)
RC_COMMUN(24)
Numbers in parenthesis indicated the pin number on the DB25 connector.
* The GPIO board can be used to manage presets. See section 9.4.2 for more détails.
10.2.3.
Remote monitoring function pinout
Event
Remote Monitoring
Output name
Common
LOCAL
RM1
REL1_RT(1)
REL1_C(14)
FAULT
RM2
REL2_RT(2)
REL2_C(15)
WARNING
RM3
REL3_RT(3)
REL3_C(16)
RF (ON/OFF)
RM4
REL4_RT(4)
REL4_C(17)
ON
RM5
REL5_T(18)
REL5_C(6)
OFF
RM6
REL5_R(5)
REL5_C(6)
VSWR
RM7
REL6_RT(19)
REL6_C(7)