System:
See chapter 10 for a description of GPIOs. Mask and State are
equivalent to .MASK and .STATE serial commands described
section 10.2.5.
For a list of control and monitoring functions, please see
sections 10.2.2 and 10.2.3.
8.2.3.
Saving parameters
With the application you may also save parameters, before upgrading or as a
backup for instance.
Select the Files / Save menu.
Select the location and name for the backup file. Default name is
module_type_serial_number.conf.
To load a previously saved configuration, use the Files / Load menu.
Loading or saving a configuration file stops real time display of parameters. Simply click the “Start” button on the
main window to retrieve them again.