User Manual
DIGILINE Series
Page 25
DIGILINE 8 / DIGILINE MX
From here the process is identical, in the list of commands (Commands List) select the wished command
to edit.
The values introduction allows certain rules:
a. Parameter Range type that incorporate the following text:
Range (number, [first-last], [firs-last,another])
In this case the value can be numerical referred to a single channel:
1
for channel 1.
We can set a range of channels in brackets (
[ ]
) and separated with a hyphen (
-
):
[1-4]
, in this case we have selected the first 4 channels.
We may also collect both previous methods separating with commas (
,
):
[1-4], 6
. In this case we have selected the channels 1-4 and 6.
We can also select alternate channels:
[1,3,6]
allows us to select channels 1, 3 and 6 only.
As a last resort selection, we can make the following value:
*
. In this way you select
ALL CHANNELS
.
The use of these symbols allows us to reduce the number of commands.
b. Float type parameters that include the following text:
Float (float number)
and in description
(1 or 0)
Here are parameters of two states:
0
if not want to activate this parameter or
1
to activate
c. Float type parameters that include the following text:
Float (float number)
and in description
(in dBs)
In this case these parameters allow edit the value in dBs.
d.
Float (float number)
and in description
(negative for decrecement)
If the value is negative (
placing a dash (-) before the
value
), this value reduces the value previously established in the amount of dBs marked, and a positive value
(
no hyphen in front
) increases it.
Float type parameters that include the following text:
In this case these parameters allow edit the value in dBs.
In this example we used the command
Output Gain: Mute with Fade
, you can select an output and
take it out of the state or a certain level Mute fade.
We applied that command on channels 1 to 4 and 6
[1-4,6]
and activated the Mute status (
1
) in
the second line parameters.
In this example we used the command
Output Gain: Increment
, which lets you select an output and
increase or decrease the gain value using the second line.
We applied that command on channel 2 by typing
2
in the first parameter and writing
-5
in the second, of
This way, we will reduce the value 5dB previously had output number 2.