You can see that the unit in the
PROJECT INSPECTOR
has a blue colour circle close to the name, it means that
both units are desynchronized.
Press on "
ReSynch
" button. It will appears to options: Device and Local, asking you which device is the correct one,
Device
for physical device or
Local
for information present in the software.
Choose the desired option, the sotware will synchonize both device, loading the preset from our choice.
After this action, the point together the device in PROJECT INSPECTOR will change to green colour.
NOTE: This circumstance also occurs in the case of load a device from the library and setting it, creating
and saving presets. After, when you want to connect and load this information on a physical DIGILINE, both
devices will be different, therefore they need to be synchronized. In that case, the correct choice will be
Local.
3.3. GPI
DIGILINE devices incorporate GPIs (General Purpose Input), 4 GPI for DIGILINE 8 and 12 GPI for DIGILINE MX
Also, both devices incorporate LMI input. These inputs are contacts. We can assign to them commands to be executed
in both states: When the GPI is activated or deactivated.The LMI is a microphone analog input that, from the selected
threshold, allows to execute the assigned commands. LMI is very adequate as talkover.
GPI interface is accessible through
GENERAL
tab.
User Manual
DIGILINE Series
Page 22
DIGILINE 8 / DIGILINE MX
Hysteresis cycle
When the input is greater than High
Level, the state pass to ON ACTIVATE.
When the input is less than Low
Level, the state pass to ON DEACTIVATE.
The Low and High level
must be set bettween 0 to
4000, When "0" means 0V
and "4000" means 3V.
LMI setup