7 181 465 347 (01.07)
30
Rectifying faults
11.
Is flue gas CO
2
level incorrect
1)
?
yes:
B
Adjust to correct level.
B
Press
, does appliance restart???
EA?
no:
↓
12.
B
Activate menu option
Show serv-
ice parameters
.
B
Select
5.1 Permanent ignition.
Continuous ignition OK?
yes:
↓
no:
↓
13.
Ignition lead connected to ignition
electrodes?
yes:
↓
no:
B
Connect cable to ignition electrode.
B
Press
, does appliance restart???
EA?
14.
Ignition cable connector engaged in
switchbox?
yes:
↓
no:
B
Power OFF the appliance.
B
Engage ignition cable connector in switchbox.
B
Turn ON the appliance.
B
Press
, does appliance restart???
EA?
15.
Ignition cable defective?
yes:
B
Power OFF the appliance.
B
Replace ignition cable.
B
Turn ON the appliance.
B
Press
, does appliance restart???
EA?
no:
↓
16.
B
Select
3.3 Ionisation current
.
Measured ionisation current medium
or high?
yes:
↓
no:
↓
EA
and
flashing.
During operation: flame not detected
Check
Action
Содержание GREENSTAR HE combi Series
Страница 174: ...7 181 465 347 01 07 50 Appendix...
Страница 175: ...7 181 465 347 01 07 Appendix 51...
Страница 176: ...Appendix...