7 181 465 347 (01.07)
Rectifying faults
31
17.
Electrode assembly defective?
B
Power OFF the appliance.
B
Remove electrode assembly.
Electrodes worn out?
yes:
B
Replace electrode assembly.
B
Turn ON the appliance.
B
Press
, does appliance restart???
EA?
↓
no:
B
Refit electrode assembly.
B
Turn ON the appliance.
B
Press
, does appliance restart???
EA?
↓
18.
Check if the 20-pin connector lead
assembly is damaged.
B
Power OFF the appliance.
B
Change the 20-pin connector lead assembly.
B
Turn ON the appliance.
B
Press
, does appliance restart???
EA?
19.
The PCB control board is damaged.
B
Power OFF the appliance.
B
Disconnect the boiler electrical connection.
B
Change PCB control board.
B
Reconnect the boiler electrical connection.
B
Turn ON the appliance.
1)
See installation instructions
EA
and
flashing.
During operation: flame not detected
Check
Action
Содержание GREENSTAR HE combi Series
Страница 174: ...7 181 465 347 01 07 50 Appendix...