6 720 610 597 GB (03.02)
14
Installation
3.5
Wall mounting frame assembly
B
Take the wall mounting frame out of the package and
screw together with 6 screws as shown in fig. 7. Use
the outer lugs on the top and bottom horizontal sec-
tions for the appliances that are 512 mm wide.
Fig. 7
B
Hold the wall-mounting frame against the wall ensur-
ing that it is vertical.
B
Mark the position of the flue duct hole if a rear flue is
to be used. Refer to fig. 1 and 16.
B
Mark the holes for the wall mounting frame onto the
wall, drill and plug the holes and screw the wall
mounting frame to the wall with the screws provided.
Fig. 8
B
Screw the pre-plumbing manifold with two screws to
the wall mounting frame.
Fig. 9
3.6
Pre-piping the system
Fig. 10 Manifold
43
CH flow
47
CH return
112
Gas cock
171
Domestic hot water
172
Cold water relief
B
A drain tap should be fitted at the lowest point of the
central heating system.
B
WRAS approved filling loop must be fitted.
6 720 610 597-06.1O
6 720 610 597-07.1O
6 720 610 597-08.1O
200
260
6 720 610 576-06.1O
35
120-130
50
47
43
172
112
171
Содержание GREENSTAR HE combi Series
Страница 174: ...7 181 465 347 01 07 50 Appendix...
Страница 175: ...7 181 465 347 01 07 Appendix 51...
Страница 176: ...Appendix...