LEMCOM EtherNet/IP™ - User manual
Network configuration
COVAL - LMEIP-UK-D-1155UM0067
15/42
Figure 9 - LEMCOM Manager and LEMCOM Web Server preview
NETWORK CONFIGURATION
Either you use a standalone master module or an island, the first step before using LEMCOM is to
set the network settings of the master module to make it
“visible” on the factory network.
6.1
Computer network settings
To make first configuration easier, it is recommended to use a direct cable connection (M8 / RJ45)
between the computer that will be used for configuration and the master LEMCOM.
Figure 10 - Direct connection between a LEMCOM island and a computer
Considering it is the first time the LEMCOM is used, its default network settings are:
Parameter
Factory setting
IP address
10.3.182.163
Default gateway
10.3.1.1
Subnet mask
255.255.255.0
DHCP
OFF
RJ45
–
M8 CABLE
24V DC
POWER SUPPLY
COVAL Bus
Termination