![Wood-mizer LT30 Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/wood-mizer/lt30/lt30_safety-setup-operation-and-maintenance-manual_994502117.webp)
Troubleshooting Guide
Electrical Problems
Troubleshooting Guide
30S97doc041910
6-5
6
PROBLEM
CAUSE
SOLUTION
Up/Down Or Power Feed
Motors Overheat And Lose
Power.
System overload or bind
occurred.
Correct problem (
). Allow motor to cool
before restarting.
Normal operation factors
exceeded (eg: up/down con-
trol jockeyed excessively).
Allow motor to cool before
restarting.
Everything Works And Then
Cuts Out - Works Again.
Bad battery, fuse, or ground
connection.
Check and tighten connec-
tions.
Nothing Works Electrically.
Dead battery.
Check for short circuit or turn
OFF key.
Blown fuse.
Replace.
Corrosion on battery post.
Remove connection and clean
posts.
Battery Will Not Stay Charged.
Key switch left ON.
Turn switch OFF when not in
use.
Short in system.
Visually check for bare wires
and/or have checked.
Charging system not function-
ing.
Have charging system
checked by authorized dealer.
Bad battery cells.
Check fluid levels and add
proper solution
Idle improper.
Adjust low end RPM per
engine manual.
Loose alternator belt.
Check belt tension and tighten
if necessary.
Loose connections at LED cir-
cuit board or alternator.
Check and tighten connec-
tions.