Troubleshooting Guide
Power Feed Problems
Troubleshooting Guide
30S97doc041910
6-7
6
6.3
Power Feed Problems
WARNING!
Disconnect and lockout power before perform-
ing any service to the electrical system. For battery-pow-
ered equipment, disconnect the negative battery terminal
cable. Failure to do so may result in injury and/or electrical
system damage.
NOTE:
The power feed circuit board is equipped with LED lights to help determine if the
circuit board or feed rate switch are the cause of any feed problems you may encounter.
for instructions.
PROBLEM
CAUSE
SOLUTION
Power Feed Is Jerky At Low
Speeds Or Does Not Move
Until Speed Is Above Halfway
Mark.
Drum switch is dirty.
Clean drum switch and lubricate
with contact grease supplied by
Wood-Mizer.
Drum switch contacts are bad
Check that contacts are in good
condition and positively close cir-
cuit.
Components are loose or
wires are broken.
Replace or repair PC board.
Power Feed Is Jerky When
Shaft Of Feed Rate Dial Is
Moved Back And Forth.
Variable speed switch is bad -
perform the variable speed
switch test.
Replace variable speed switch.
Power Feed Is Jerky, But
Power Feed Motor Runs Prop-
erly At All Speeds.
Problem is mechanical.
Refer to the Mechanical Test.
Power Feed Is Sluggish, Trips
Circuit Breaker Or Current
Limit.
Sawdust buildup in power
feed cover.
Remove power feed belt cover
and remove sawdust.