Troubleshooting Guide
Circuit Breaker Operation
6
6-18
30S97doc041910
Troubleshooting Guide
6.10 Circuit Breaker Operation
LT30 Super
Rev. G3.00+
LT40 Super
Rev. G4.00+
Sawmill controls are equipped with manual reset circuit breakers to protect the electrical
circuits.
See Figure 6-4.
The power feed and up/down breakers are externally mounted at the
front of the control box. The blade guide, accessory, ignition, start and board return break-
ers are located inside the control box. Remove the circuit breaker panel from the control
box to access the internal breakers.
NOTE:
If the breaker is still hot, you may not be able to
reset it immediately. Allow the breaker to cool for a few min-
utes before attempting to reset.
FIG. 6-4
External
Power Feed
Circuit Breaker
External
Up/Down
Circuit Breaker
3H0550-2
Internal Circuit Breakers (Remove Panel)
Blade
Guide
Accessory
Ignition
Start
Board
Return