SETUP & OPERATION
Starting the Machine
SETUP & OPERATION
BMS500/600doc121319
2-2
2
The machine can be operated at the temperature range of 5
o
C to 40
o
C (41
o
F to
104
o
F)and at the humidity of up to 80 percent.
For cooling the grinding wheel, use only oil meeting the specifications:
.
Do not use any other liquids, e.g. water.
The position of the sharpener operator is shown below.
See Figure 2-2.
The operator must always wear safety goggles and protective gloves when operating the
sharpener.
There must be at least 70cm (27.56") of free space around the sharpener.
Have a qualified electrician install the power supply. The power supply should meet the
specifications given in the table below.
FIG. 2-2
Sharpener Type
Voltage
Fuse
Disconnect [A]
Recommended
Wire Size
BMS500AU
BMS600AU
230V [ L1+N (L1=230V, N-neutral)]
230V [L1+L2 (230V phase-to-phase voltage)]
10 Amp
minimum 1.5 mm
2
(min. 15 AWG)
BMS500B(S/U)
BMS600B(S/U)
3 x 230V
10 Amp
minimum 1.5 mm
2
(min. 15 AWG)
BMS500C(S/U)
BMS600C(S/U)
3 x 460V
10 Amp
minimum 1.5 mm
2
(min. 15 AWG)
TABLE 2-1
70cm (27.56")
70cm (27.56")
354cm
2
28c
m
(
89.
76"
)
70cm
70cm
(27.56")
(27.56")
(139.37")
Operator’s
Position