SETUP & OPERATION
Index Arm Stroke Adjustment
SETUP & OPERATION
BMS500/600doc121319
2-10
2
2.8
Index Arm Stroke Adjustment
The sharpener indexer can be adjusted depending on the tooth spacing of the blade. To perform this
adjustment, position appropriately the stroke adjustment plate located on the sharpener cam.
Unscrew the hex socket head screws mounting the plate to the cam, unscrew the indexer shaft,
rotate the cam so that a given indicator on the plate is aligned with the indicator on the cam, replace
the stroke adjustment plate mounting screws and install the indexer shaft in the hole nearest to the
stroke indicator/adjustment plate mounting screw. The index arm can be adjusted for the following
tooth spacings:
Tooth Spacing
.5" / 12.7mm
.656" / 16.7mm
.75" / 19mm
.875" / 22.2mm
1" / 25.4mm
1.125" / 28.6mm - 1.250"/31.75mm
TABLE 2-2
FIG. 2-9
IS203_031_A
Stroke Adjustment
Plate Mounting Screw
(Hex Socket Head
Cap)
Indexer Shaft
Sharpener
Cam
Stroke
Adjustment
Plate
Stroke Adjustment
Plate Mounting Screw
(Hex Socket Head
Cap)
Indicator on Cam
Indicator on Stroke
Adjustment Plate