Safety & General Information
Control Panel Components
Safety & General Information
BMS500/600doc121319
1-8
1
NOTE:
Before starting the cam motor, place the Feed Rate Dial in the "0" position.
To turn off the cam motor and unclamp the blade, press "STOP" on the Cam Motor Start/Stop
Switch.
Grinder Motor Start/Stop Switch
Starts/stops the grinder motor.
Oil Flow Start/Stop Switch
Starts/stops the coolant pump motor.
Tooth Counter
Sets/keeps track of number of teeth to be sharpened and sharpening cycyles.
The display shows a preset number of blade teeth to be sharpened. To set this number, use the
"UP" and "DOWN" buttons located under the display window. When sharpening cycle is started
(with the Sharpening Cycle Start Button), the dispay will be showing current number of teeth
that have been sharpened. After reaching the set number of teeth, "End" will be diplayed and
the tooth counter has to be reset before the sharpener can be operated again. To reset, press
the "RESET" button.
If you need to sharpen the blade more then once, before starting set the cycles number using
the "CYCLE" button (for ex. if you want to set three cycles, press "CYCLE" button three times).
HINT:
We advise to not change the cycle number from 1 cycle. If the blade needs to go around
the sharpener more than once, complete first cycle and readjust for blade height and face grind
to ensure you are grinding the full profile
The diagnostic button "F" is used to check the outputs of the counter. Press and hold the "F"
button to start the diagnostic proces. When it is finished, the counter will go back to normal
operation.
Disconnect Switch (located on the main electric box)
Disconnects/connects power to the machine.
Turn the switch to the horizontal position ("0" - OFF) to lock out all electrical power during
service or when the sharpener is not in use.
NOTE:
Place the disconnect switch in the "0"
position before opening the electric box door.
To reconnect power to the machine, turn the switch to the vertical position ("1" - ON).