Meter Type and Reference Menu
The
Meter Type and Reference Menu
allows you to define the level meter scale,
float, bar and reference.
Figure 4–11: Meter Type and Reference Menu
1.
Scale: Pressing this button and then rotating the Trim knob steps through
the scales for the level meters. Six selections are available as shown in
Table
4–1
below.
Table 4–1: Meter Limits and References
Scale
Bottom
Limit
Top
Limit
Default
Reference
Default Color
Bounds
Default
Ballistics
Lower
Upper
Float
Bar
AES
-72 dBFS
0.0 dBFS 0 dBFS = 0 dBFS
-30 dBFS
-20 dBFS
IEC
Type I
VU
VU
-45 dBr
+3.5 dBr -20 dBFS = 0 dBr
-3 dBr
0 dBr
-
VU
Ext VU
-56 Br
+16.0
dBr
-20 dBFS = 0 dBr
-10 dBr
0 dBr
-
VU
BBC
(EBU)
-13.25 dBr
+13.0
dBr
-18 dBFS = 0 dBr
0 dBr
8 dBr
-
IEC
Type II
Nordic -44
dBr
+12.5
dBr
-18 dBFS = 0 dBr
-10 dBr
0 dBr
-
IEC
Type I
DIN
-53 dBr
+5.5 dBr -15 dBFS = 0 dBr
-5 dBr
0 dBr
-
IEC
Type I
2.
Float: Pressing this button and then rotating the Trim knob adjusts the
ballistics of the floating segment. The possible settings are shown in Table 4-
2.