Page 16
To integrate it into your digital network, you need to set its address to the source to
be monitored. You must use the emSET configuration software to set up this option.
It is available from Wohler Technologies Technical Service. The procedure to
accomplish this is described in the
SFP-2022-6 / SFP-2110 Setup Guide
(part
number 821822), which is available at
ftp://ftp.wohler.com/Download-from-
Wohler/DoNotDelete/Emset
Channel Meters and Touch Operations
The audio mixer terminology of “solo” is used in this manual when referring to
muting all but a specific audio channel or pair.
Audio meters are displayed on touchscreen LCD display(s) in up to 8 channel pairs,
as shown in Figure 2-8.
Figure 2-8: Audio Level Meter Screen
1.
Channel Identifiers
: Above the level meters are the Channel Identifiers.
They indicate the consecutive channel numbers in the selected source.
An arrow pointing to the left indicates that this is a left channel and
will be monitored in the left speaker.
An arrow pointing to the right indicates that this is a left channel and
will be monitored in the right speaker.
A square indicates that this is a center channel and will be monitored
in both speakers.
The symbol shown on channels 7 and 8 in Figure 2-8 indicates
that this channel pair is a Dolby bitstream. Refer to the Dolby
1
2
3
8
7