5.

 

Complementary information 

5.1

 

Force sensor types 

WObit company has a broad offer of force sensors in range from single Newton’s up to hundreds of 
kilo  Newton’s.  Depends  on  assembly  and  way  of  measuring  force  (tension,  compression)  are 
available sensors with different shapes (table below). 
 

Beam 

 

To measure tension force. Range of measured force 0..350 N. 
Example of models: K200, K300 

S-beam 

 

To measure large tension force. Range of measured force 0..75 kN. 
Example of models: K1401, K1501, K1505, K1506, K1600 

Round 

 

To measure large and small tension force. Range of measured 
force 0..100 kN. 
Example of models: KB52, KB82, KMB19, KMB25, KMB31, KMM30, 
KMM50, KMM60, 

Round with 

shaft 

 

To measure large and small tension and compression force. Range 
of measured force 0..50 kN. 
Example of models: KMM20, KMM40 

Cylindrical 

 

To measure large tension and compression force. Range of 
measured force 0..200 kN. 
Example of models: K1101  

5.2

 

Sensor measuring range 

Rated load

 for sensor it is a size of force, which specifies 

top value of measuring range  (given value  for sensor as 

bridge range

 -

TRA

 in N). 

 

Applied  load

  is  the  biggest  force,  which  have 

unambiguous  connection  between  force  and  output 
signal (signal value is changing linear in relation to force). 
It can count max. M

150%

 of sensor range (bridge). 

 

Cut-off  load 

is  the  biggest  force,  which  can  take  each 

sensor  without  it  damage.  It  can  count  max. 

200%

  of 

sensor range. 
 

Destroying  load 

means  force  applied  to  sensor  Shaft, 

which exceeding can cause to mechanical damage of the 
sensor. 
 
Constant of e.g. KMM60 sensor  is 1,5mV/V 

 2%. Error of the sensor is specified by following values: 

tolerance  of  linearity    0,2%  of  measuring  range,  zero  tolerance  2%  of  measuring  range,  hysteresis  
0,2% of range and creep measured in  time of  30 minutes 0,1%. Temperature factor of zero point 

Destroying load 

>200% F 

Cut-off load 

+200% F 

Applied load 

+150% F 

Rated load 

+100% F 

Me

asurin

g ra

n

ge

 

Zero load 

0 [N] 

Rated load 

-100% F 

Applied load 

-150% F 

Cut-off load 

-200% F 

Destroying load 

<200% F 

Содержание ADT42

Страница 1: ...s c 62 045 Pniewy D borzyce 16 tel 061 22 27 422 fax 061 22 27 439 e mail wobit wobit com pl www wobit com pl ADT42 User Manual 4 channel measuring module for force sensors with 0 10V 4 20mA output U...

Страница 2: ...MODBUS Communication 12 5 Complementary information 14 5 1 Force sensor types 14 5 2 Sensor measuring range 14 6 Technical parameters 15 Thank you for selecting our product This instruction will help...

Страница 3: ...the device or to fire Dismantling of the indicator housing during guarantee agreement period results in its invalidation 1 2 Assembly recommendation In the environments of unknown levels of interrupti...

Страница 4: ...of measurements from selected channels the module can be used in multi sensor weight systems ADT42 has 2 transistor outputs and 2 insulated inputs one tare input Built in operating modes enable the de...

Страница 5: ...surement data acquisition 2 3 Description of connectors and diodes Picture 1 Connector and panel description Nr Description Analog output 0 10V 4 20mA 1 GND Ground of analog output 2 AOUT 0 10V 4 20mA...

Страница 6: ...res usually have additional shielded braid which is connected with metal housing of the sensor This signal can be connected to supply ground of ADT42 but we don t recommend to do that while sensor is...

Страница 7: ...N2 0 output signal aggregate signal after tare IN2 1 output signal aggregate signal before tare Tab 2 Functions of opt insulated inputs Picture 3 Opt insulated input 2 7 Transistor outputs ADT42 has t...

Страница 8: ...s the module Good quality USB cable with length 1 5 m equipped with ferrite beads Opt insulated USB HUBs on PC side In some conditions can occur that communication won t be possible or measurement dat...

Страница 9: ...or using option Reverse the sign and zeroing channel by pressing Zero Filtration of measurement ADT42 has constant averaging filter set in range 0 99 samples and measurement mode Fast and Slow 2 Bigge...

Страница 10: ...g output A selection of signal source sent on 0 10V 4 20mA output B calibration of analog output 2 Setting of transistor outputs OUT 1 and OUT2 3 Setting of communication parameters RS485 MODBUS 4 Rea...

Страница 11: ...3 Set Output 0V for value 500 4 Set Output 10V for value 0 5 Save settings by Save button 3 3 2 Configuration of transistor outputs By using this option it is possible to configure conditions of acti...

Страница 12: ...5 CANAL1_INT INT R 0x03 Value of 2 channel 5 6 CANAL2_INT INT R 0x03 Value of 3 channel 6 7 CANAL3_INT INT R 0x03 Value of 4 channel 7 8 ANALOG_INT INT R 0x03 Value of analog output x1000 Values store...

Страница 13: ...tion table Reading of measurements from SUM_IREAL register Function 03 Register address 0 Request MODBUS MASTER ADT42 Response ADT42 MODBUS MASTER Device address 0x01 Device address 0x01 Function 0x03...

Страница 14: ...measured force 0 200 kN Example of models K1101 5 2 Sensor measuring range Rated load for sensor it is a size of force which specifies top value of measuring range given value for sensor as bridge ran...

Страница 15: ...e error 0 0025 C Measurement frequency filtration mode slow fast 1 active channel 10 Hz 80 Hz 2 active channel 1 2 Hz 10 Hz 3 active channel 0 8 Hz 6 5 Hz 4 active channel 0 6 Hz 5 Hz Time of initial...

Отзывы: