User manual  -ADT42 – 23.06.2015 – v.1.3 

   page 3 

 

1.

 

Safety and assembly rules 

1.1.

 

Safety rules 

 

 Prior to first start-up of the device carefully read the manual.  

 

 Prior to first start-up of the device make sure all cables are properly connected.  

 

 Provide  appropriate  working  conditions,  in  compliance  with  the  device   
specifications  (e.g.:  power  supply  voltage,  temperature,  maximum  current  
consumption). 

 

 Prior to any modifications of cables connections, disconnect power supply voltage.  

 

Usage  of  described  device  in  special  meaning  systems  (e.g.: medical  applications,  vehicles, 
etc.) requires use of additional safety measures against operational errors. 

 

This device can’t be used in open space. It can cause an electric shock and shorten lifetime of 
the device. 

 

 Exceeding of recommended operational parameters can lead to damage of the device or to 
fire.

 

 

 

Dismantling  of  the  indicator  housing  during  guarantee  agreement  period  results  in  its 
invalidation.  

 

1.2.

 

Assembly recommendation 

In  the  environments  of  unknown  levels  of  interruptions  it  is  recommended  to  use  the  following 
means preventing against possible interruptions of the device operation:  
 

 

Ground or zero the metal rails on which instruments are mounted, 

 

 Do  not  power  the  device  from  the  same  lines  as  high  power  devices  without  appropriate 
network filters.  

 

 

Apply  power  supply,  sensor  and  signal    cables  screening  while  screen  grounding  should  be 

connected only on one side as close to the device as possible.  

 

For  power  supply  of  the motor  please  use  twister pair  of  cables,  if  possible  equipped  with 
filters in the form of ferrite beads.  

 

 

Avoid routing control (signal) cables in parallel with or in close vicinity of power and supply 

cables. 

 

Avoid  close  vicinity  of  devices  generating  high  level  of  electromagnetic  and/or  pulse 
interference (high power loads, loads with phase or group power regulation).  

 

 
 

 
 
 

 
 
 

Содержание ADT42

Страница 1: ...s c 62 045 Pniewy D borzyce 16 tel 061 22 27 422 fax 061 22 27 439 e mail wobit wobit com pl www wobit com pl ADT42 User Manual 4 channel measuring module for force sensors with 0 10V 4 20mA output U...

Страница 2: ...MODBUS Communication 12 5 Complementary information 14 5 1 Force sensor types 14 5 2 Sensor measuring range 14 6 Technical parameters 15 Thank you for selecting our product This instruction will help...

Страница 3: ...the device or to fire Dismantling of the indicator housing during guarantee agreement period results in its invalidation 1 2 Assembly recommendation In the environments of unknown levels of interrupti...

Страница 4: ...of measurements from selected channels the module can be used in multi sensor weight systems ADT42 has 2 transistor outputs and 2 insulated inputs one tare input Built in operating modes enable the de...

Страница 5: ...surement data acquisition 2 3 Description of connectors and diodes Picture 1 Connector and panel description Nr Description Analog output 0 10V 4 20mA 1 GND Ground of analog output 2 AOUT 0 10V 4 20mA...

Страница 6: ...res usually have additional shielded braid which is connected with metal housing of the sensor This signal can be connected to supply ground of ADT42 but we don t recommend to do that while sensor is...

Страница 7: ...N2 0 output signal aggregate signal after tare IN2 1 output signal aggregate signal before tare Tab 2 Functions of opt insulated inputs Picture 3 Opt insulated input 2 7 Transistor outputs ADT42 has t...

Страница 8: ...s the module Good quality USB cable with length 1 5 m equipped with ferrite beads Opt insulated USB HUBs on PC side In some conditions can occur that communication won t be possible or measurement dat...

Страница 9: ...or using option Reverse the sign and zeroing channel by pressing Zero Filtration of measurement ADT42 has constant averaging filter set in range 0 99 samples and measurement mode Fast and Slow 2 Bigge...

Страница 10: ...g output A selection of signal source sent on 0 10V 4 20mA output B calibration of analog output 2 Setting of transistor outputs OUT 1 and OUT2 3 Setting of communication parameters RS485 MODBUS 4 Rea...

Страница 11: ...3 Set Output 0V for value 500 4 Set Output 10V for value 0 5 Save settings by Save button 3 3 2 Configuration of transistor outputs By using this option it is possible to configure conditions of acti...

Страница 12: ...5 CANAL1_INT INT R 0x03 Value of 2 channel 5 6 CANAL2_INT INT R 0x03 Value of 3 channel 6 7 CANAL3_INT INT R 0x03 Value of 4 channel 7 8 ANALOG_INT INT R 0x03 Value of analog output x1000 Values store...

Страница 13: ...tion table Reading of measurements from SUM_IREAL register Function 03 Register address 0 Request MODBUS MASTER ADT42 Response ADT42 MODBUS MASTER Device address 0x01 Device address 0x01 Function 0x03...

Страница 14: ...measured force 0 200 kN Example of models K1101 5 2 Sensor measuring range Rated load for sensor it is a size of force which specifies top value of measuring range given value for sensor as bridge ran...

Страница 15: ...e error 0 0025 C Measurement frequency filtration mode slow fast 1 active channel 10 Hz 80 Hz 2 active channel 1 2 Hz 10 Hz 3 active channel 0 8 Hz 6 5 Hz 4 active channel 0 6 Hz 5 Hz Time of initial...

Отзывы: