background image

 

www.wobit.com.pl 

User manual  -ADT42 – 23.06.2015 – v.1.3 

   page 15 

 

and  constant  is  0,1%  of  range/10

o

C.  Bridge  resistance  on  input  has  380om  ±10%  and  output 

resistance has 350om ±5%. 
 

6.

 

Technical parameters 

 

 

Mechanical parameters 

Housing dimensions: 

120 x 101 x 23 mm 

Weight:  

100 g  

Operating temperature 
range: 

5..50°C 

Protection class: 

IP20, 

Mounting 

Handle on DIN rail 

 

 

Electrical parameters 

Power supply 

12…24

 

VDC

, 150 mA + OUT1, OUT2 outputs current 

Force sensor inputs 

Sensor power supply: 5 V (also 10V sensors) 
Max. differential voltage: ±39mV, 
Resolution:  0,001% FS (for typical bridge with sensitivity 
2mV/V) Temperature error: 0,0025%/C° 
Measurement frequency (filtration mode: slow/fast) 

 

1 active channel:  10 Hz / 80 Hz   

 

2 active channel: 1,2 Hz / 10 Hz   

 

3 active channel: 0,8 Hz / 6,5 Hz  

 

4 active channel:  0,6 Hz / 5 Hz      

Time of initial annealing: about 10 min 

Digital inputs IN1, IN2 

Opt insulated, 
Low state: 0 V (max. 1 V), high state: +24 V (5…24 V) 
Min. pulse length >10 ms, 

Transistor inputs OUT1, OUT1  

Transistor OC , PNP type 
Max. ampacity: 0,5 A 
Low state: OUT = 0 V 
High state: OUT = VDC (voltage supply of the module) 

Analog output 0-10 V  

ADT42-U 

version) 

0-10 V mode : 

V min =  0,015 V, V max = 10V, max. load 20 mA 

Resolution : ±3 mV, Accuracy 10 mV (0,1% FS) 
 

Analog output 0/4-20 mA 
(

ADT42-I 

version) 

(0)4-20 mA

  

mode:

 I min = 0,1 mA, I max = 24 mA 

Resolution: ±13µA, Accuracy 0,05 mA (0,25% FS)

 

Communication 

RS485 MODBUS-RTU

, (by default: 38400bps, 8:n:1, address: 1) 

USB

: 1.1, 2.0 

 

Содержание ADT42

Страница 1: ...s c 62 045 Pniewy D borzyce 16 tel 061 22 27 422 fax 061 22 27 439 e mail wobit wobit com pl www wobit com pl ADT42 User Manual 4 channel measuring module for force sensors with 0 10V 4 20mA output U...

Страница 2: ...MODBUS Communication 12 5 Complementary information 14 5 1 Force sensor types 14 5 2 Sensor measuring range 14 6 Technical parameters 15 Thank you for selecting our product This instruction will help...

Страница 3: ...the device or to fire Dismantling of the indicator housing during guarantee agreement period results in its invalidation 1 2 Assembly recommendation In the environments of unknown levels of interrupti...

Страница 4: ...of measurements from selected channels the module can be used in multi sensor weight systems ADT42 has 2 transistor outputs and 2 insulated inputs one tare input Built in operating modes enable the de...

Страница 5: ...surement data acquisition 2 3 Description of connectors and diodes Picture 1 Connector and panel description Nr Description Analog output 0 10V 4 20mA 1 GND Ground of analog output 2 AOUT 0 10V 4 20mA...

Страница 6: ...res usually have additional shielded braid which is connected with metal housing of the sensor This signal can be connected to supply ground of ADT42 but we don t recommend to do that while sensor is...

Страница 7: ...N2 0 output signal aggregate signal after tare IN2 1 output signal aggregate signal before tare Tab 2 Functions of opt insulated inputs Picture 3 Opt insulated input 2 7 Transistor outputs ADT42 has t...

Страница 8: ...s the module Good quality USB cable with length 1 5 m equipped with ferrite beads Opt insulated USB HUBs on PC side In some conditions can occur that communication won t be possible or measurement dat...

Страница 9: ...or using option Reverse the sign and zeroing channel by pressing Zero Filtration of measurement ADT42 has constant averaging filter set in range 0 99 samples and measurement mode Fast and Slow 2 Bigge...

Страница 10: ...g output A selection of signal source sent on 0 10V 4 20mA output B calibration of analog output 2 Setting of transistor outputs OUT 1 and OUT2 3 Setting of communication parameters RS485 MODBUS 4 Rea...

Страница 11: ...3 Set Output 0V for value 500 4 Set Output 10V for value 0 5 Save settings by Save button 3 3 2 Configuration of transistor outputs By using this option it is possible to configure conditions of acti...

Страница 12: ...5 CANAL1_INT INT R 0x03 Value of 2 channel 5 6 CANAL2_INT INT R 0x03 Value of 3 channel 6 7 CANAL3_INT INT R 0x03 Value of 4 channel 7 8 ANALOG_INT INT R 0x03 Value of analog output x1000 Values store...

Страница 13: ...tion table Reading of measurements from SUM_IREAL register Function 03 Register address 0 Request MODBUS MASTER ADT42 Response ADT42 MODBUS MASTER Device address 0x01 Device address 0x01 Function 0x03...

Страница 14: ...measured force 0 200 kN Example of models K1101 5 2 Sensor measuring range Rated load for sensor it is a size of force which specifies top value of measuring range given value for sensor as bridge ran...

Страница 15: ...e error 0 0025 C Measurement frequency filtration mode slow fast 1 active channel 10 Hz 80 Hz 2 active channel 1 2 Hz 10 Hz 3 active channel 0 8 Hz 6 5 Hz 4 active channel 0 6 Hz 5 Hz Time of initial...

Отзывы: