12.1.3- Time Settings
Proper time settings are important for producing accurate time stamps for events, recorded video, and
captured snapshots.
Server Time
Displays the Current Time and Date for the Cameras
Date Format
Select the desired format to display the Date.
Time Zone
Time Zone can only be adjusted when NTP, or Manual are selected.
Enable Daylight
Savings
When enabled, Daylight Saving Time Start and Stop parameters can be configured.
By default this is set to On.
NTP
Keeps camera time synchronized with a Network Time Server.
Recommendation:
We recommend that the default (pool.ntp.org) be used as it
pulls from multiple redundant servers.
Synchronize
With PCs Time
Sets the camera date and time to that of the local PC, and then shifts to the
camera’s internal clock. After applying, Time Setting is indicated as Internal Clock.
Manual
Allows for manual entry of the date and time, and then
shifts to the camera’s internal
clock.
Internal Clock
Shifts the camera to using the Internal Clock only. Automatically selected after using
Synchronize with PC’s time or Manual time settings.
12.2- User Management
There are 2 levels of users: Administrator which is the default Admin account, and Guest accounts. The
Admin account is the only account that can be set as an administrator. An unlimited number of guest
accounts can be added.
Anonymous
User Login:
When Yes is selected the Cameras can be accessed without the use of login
credentials. These users have the ability to:
View Video
Use Zoom, Mute, Video (Full), Record, and Picture
Change the GUI size
Recommendation:
To avoid unwanted access to the Cameras we recommend
that this feature be set to NO.
Add User:
Usernames can only contain Letters and Numbers. Spaces and special characters
such as underscores will not be accepted.
Note: Only 1 Administrator account can be created.
User List:
User passwords can be changed by selecting Edit. Names cannot be changed. To
change a Username, the account must be deleted and recreated.