Figure B-2.
CSA Control Drawing
A
WEEK
3
ISSUE
MODIF. ORDER NO.
WEEK
MODIF. ORDER NO.
ISSUE
WEEK
MODIF. ORDER NO.
ISSUE
2
B
C
SHEET
ISSUE
A3.DWG, 061024
MATERIAL
TITLE
FILE
DWG NO.
SCALE
PRODUCT CODE
DOC. TYPE
1 ST ANGLE
OTHERWISE STATED:
FINISH, UNLESS
3
ISSUED BY
APPROVED BY
2
TOLERANCES, UNLESS OTHERWISE STATED:
FOR CASTING: ISO 8062
FOR MACHINING: ISO 2768
ALL DIMENSIONS ARE IN MILLIMETRES.
WEEK
WEEK
FOR WELDING: SS-EN ISO 13920
WILL BE PROSECUTED. ROSEMOUNT TANK RADAR AB, SWEDEN.
OR BROUGHT TO THE KNOWLEDGE OF A THIRD PARTY. CONTRAVENTION
THE COPYRIGHT/OWNERSHIP OF THIS DOCUMENT IS AND WILL REMAIN
OURS. THE DOCUMENT MUST NOT BE USED WITHOUT OUR AUTHORIZATION
1
A
ORIGINALFORMAT A3
B
1
C
mK
CT10
A, E
6.3
ONLY THE CSA APPROVED 375 FIELD COMMUNICATOR MAY BE CONNECTED TO THE HART TERMINALS.
ROSEMOUNT 2160 TRANSMITTERS ARE CSA APPROVED AS THE FOLLOWING:
INTRINSICALLY SAFE FOR USE IN CLASS I, DIVISION 1, GROUPS A,B,C,D HAZARDOUS LOCATIONS TEMPERATURE CODE T3C
2160X**S*
2160X**E*
HAZARDOUS AREA
CERTIFIED PRODUCT
ALTERATIONS TO THIS DOCUMENT MUST BE APPROVED BEFORE IMPLEMENTATION.
MINIMUM AMBIENT AIR TEMPERATURE (Ta) = -50
C
MINIMUM PROCESS TEMPERATURE (Tp) = -40
C
MINIMUM AMBIENT AIR TEMPERATURE (Ta) = -50
C
MINIMUM PROCESS TEMPERATURE (Tp) = -70
C
NOTES:
INSTALLATION OF EQUIPMENT INCLUDING ANY GROUNDING ARRANGEMENT TO BE IN
1.
ACCORDANCE WITH CANADIAN ELECTRICAL CODE RECOMMENDED PRACTICE FOR INSTALLATION OF INTRINSICALLY SAFE CIRCUITS, OR THE INTRINSICALLY SAFE EQUIPMENT INSTALLATION PRACTICE IN THE COUNTRY OF USE.
SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
2. AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SECURITE INTRINSIQUE.
WARNING: THE SURFACE RESISTIVITY OF THE ANTENNA IS GREATER THAN 1GOhm. TO AVOID
3.
ELECTROSTATIC CHARGE BUILD-UP, IT MUST NOT BE RUBBED OR CLEANED WITH SOLVENTS OR A DRY CLOTH.
WARNING: THE POWER MODULE MAY BE REPLACED IN A HAZARDOUS AREA. THE POWER
4.
MODULE HAS SURFACE RESISTIVITY GREATER THAN 1 GOhm AND MUST BE PROPERLY INSTALLED IN THE WIRELESS DEVICE ENCLOSURE. CARE MUST BE TAKEN DURING TRANSPORTATION TO AND FROM THE POINT OF INSTALLATION TO PREVENT ELECTROSTATIC DISCHARGE BUILD-UP.
FOR FURTHER INFORMATION REFER TO MANUAL 00809-0100-4160.
5.
Temperature Classes
Maximum Ambient Air
Temperature (Ta)
Maximum Process Temperature (Tp)
T3C, T2, T1
70
C
100
C
T3C, T2, T1
60
C
115
C
T3, T2, T1
50
C
150
C
Temperature Classes
Maximum Ambient Air
Temperature (Ta)
Maximum Process Temperature (Tp)
T3C, T2, T1
70
C
115
C
T3, T2, T1
65
C
185
C
T2, T1
60
C
260
C
X
XX
DJS
52
X
0
1:2
ACAD
CSA INTRINSICALLY SAFE
CONTROL DRAWING, 2160
71097/1271
4
1/1
------
44
7
MOB-00062
30
ST7345
23
33
ST7435
Содержание Rosemount 2160 WirelessHART
Страница 2: ......
Страница 18: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 1 10...
Страница 56: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 3 14...
Страница 70: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 5 10...
Страница 76: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 6 6...
Страница 92: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 A 16...
Страница 98: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 B 6...
Страница 99: ......