Aug. Winkhaus GmbH & Co. KG
∙ Hessenweg 9 ∙ 48157 Münster ∙ T +49 251 4908 - 0 ∙ [email protected] ∙ www.winkhaus.de
ETB-IM
14
Operating manual
Present the identification medium slowly and hold it in front of the interaction
surface marked with coloured semicircular crescents until authorisation is
complete, which is confirmed with a green LED and an acoustic signal.
All signals are always output following actuation with an identification
medium belonging to the system. No signals are given with keys that do not
belong to the system.
Presentation of authorised identification medium
Signal duration 500 ms green LED and 200 ms acoustic signal, after the
authorisation check and after the release position is reached (not in the
permanent release state). The end of the release is not signalled. The
actuators noticeably move back.
Activation of the actuators for engaging the handle. The actuators are
disengaged once the release time has expired.
Presentation of unauthorised identification medium belonging to the
system
Signal duration 750 ms (red LED and acoustic signal), after the authorisation
check (not in the permanent release state).
Actuator disengages if no permanent release is set up, regardless of the
current position. Switched on permanent release remains in place.
9.2 Individual release
9 Operation
9.1 Identification media
The electronic door handle can be actuated with all authorised identification
media belonging to the system (user key, premium key, user key with
additional transponder, active key, key fob TAG, cards and mechatronic
keys).